The silentLab acoustic enclosures have been especially developed to reduce the noise level generated by vacuum pumps and compressors used with SEMs, TEMs, FIB-SEM, mass spectrometers, pumped air-locks, sample preparation and analytical systems. If there is no opportunity to move the vacuum pumps to a separate room, the noise level generated by the pumps and/or the water chiller can be irritating and distracting. Using a silentLab acoustic enclosure will significantly reduce the noise level to acceptable levels and allows operators to concentrate on the task at hand.
The silentLab acoustic enclosures are sophisticated safe soundproofing boxes which are placed over the noisy vacuum pump or water chiller. They facilitate power and vacuum pumping lines, provide cooling and will let the vacuum pump or water chiller operate at full specifications. The silentLab systems were originally designed for SEMs, TEMs and FIB-SEM systems, but equally useful for other systems with noisy rotary vacuum pumps. The silentLab 3 has been specifically designed for smaller pumps used with SEM sputter coaters, EM carbon coaters and vacuum ovens. The silentLab 5 is intended for analytical systems with larger noisy rotary vacuum pumps. The silentLab 4-compact is a smaller version of the silentLab 4 and intended for labs with limited floorspace.
Features of the premium silentLab noise reduction boxes are:
Specifications for the silentLab acoustic enclosures for single vacuum pumps with forced ventilation when pump is switched on
Model | SilentLab 3 |
silentLab 4 |
silentLab 4 compact |
silentLab 5 |
silentLab 6 S-4 |
|
Product # |
|
|||||
Noise reduction |
15dB |
15/18dB |
15/18dB |
15/18dB |
15dB |
|
Designed for |
Small pump |
Medium pump |
Medium pump |
Large rotary pump |
Heavy duty rotary pump |
|
Compatible with |
Pfeiffer UNO 5 |
Edwards RV8 / RV12 / RV18 |
Edwards RV8 / RV12 |
Edwards E2M28 |
Sogevac SV40BI |
|
Fans |
2 |
2 |
4 |
2 |
4 – Temp. controlled |
|
Voltage |
230/115V |
230V / 115V |
230V/115V |
230V / 115V |
230V / 115V |
|
Power rating |
Fused 2300W |
Fused 2300W |
Fused 2300W |
Fused 2300W |
Fused 2300W |
|
Power connections |
IEC socket |
IEC socket |
IEC socket |
IEC socket |
IEC socket |
|
Outside dimensions |
350 x 400 x 600mm |
500 x 500 x 800mm |
500 x 380 x 680mm |
500 x 500 x 900mm |
500 x 600 x 800mm |
|
Inside dimensions |
250 x 350 x 500mm |
400 x 450 x 700mm |
400 x 280 x 580mm |
400 x 450 x 800mm |
400 x 500 x 700mm |
|
Weight |
16kg |
20kg |
19kg |
23kg |
23kg |
|
Specifications for the silentLab acoustic enclosures for 2 rotary vacuum pumps or air compressor
Model | silentLab 6 DUO-z |
SilentLab 9 DUO-i |
silentLab 8 |
Product # |
|||
Noise reduction |
15dB |
15dB |
15dB |
Designed for |
Two rotary pumps |
Two rotary pumps |
Air compressor |
Compatible with |
2 x Edwards RV12 |
2 x Edwards RV12 |
Bambi PT5 |
Fans |
4 |
4 – Temp. controlled |
2 |
Voltage |
230V / 115V |
230/115V |
230V / 115V |
Power rating |
Fused 2300W |
Fused 2300W |
Fused 2300W |
Power connections |
IEC sockets |
IEC sockets |
IEC sockets |
Outside dimensions |
500 x 600 x 800mm |
500 x 600 x 800mm |
450 x 500 x 585mm |
Inside dimensions |
400 x 500 x 700mm |
400 x 500 x 700mm |
350 x 400 x 485mm |
Weight |
23kg |
23kg |
19kg |
Due to the footprint of the silentLab box, vacuum lines might need an extension between 1-2m.
When requesting a quotation, please specify the model and make of SEM, TEM, FIB-SEM, sample preparation or other analytical system and model and make of vacuum pump.
Delivery and installation for Austria, Belgium, Germany, Netherlands, Luxemburg and Switzerland optionally available at additional costs.
Quotation information for the silentLab acoustic enclosures for EM labs (230V):
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|